INVT GD20 series GD20-1R5G-S2 three-phase universal heavy-duty frequency converter

1
MOQ
467
harga
INVT GD20 series GD20-1R5G-S2 three-phase universal heavy-duty frequency converter
fitur Galeri Deskripsi Produk bicara sekarang
fitur
Spesifikasi
Bahan: Baja Tahan Karat, Plastik, Aluminium
Jenis masukan: Input Digital dan Analog
Kondisi: Baru Asli Dengan Segel
Skalabilitas: Ekspansi Modular Didukung
Tegangan Keluaran: 0-480 V AC
Distorsi Harmonik: <5% dengan filter opsional
Industri: MANUFAKTUR
Kisaran suhu pengoperasian: -10°C hingga 50°C
ResponseTime: 1 mdtk hingga 10 mdtk
Ukuran: 150mmx100mmx75mm
Konsumsi daya: Bervariasi berdasarkan model, biasanya 10-50W
metode pendinginan: Pendinginan udara paksa
Tegangan masukan: 24V DC / 110V AC / 220V AC
Waktu Akselerasi/Deselerasi: 0,1 hingga 6000 detik
Bagian No: MMS 6210
Menyoroti:

INVT GD20 frequency converter

,

three-phase heavy-duty VFD

,

universal variable frequency drive

Informasi dasar
Tempat asal: Cina
Nama merek: INVT
Nomor model: GD20-1R5G-S2
Syarat-syarat pembayaran & pengiriman
Kemasan rincian: Bagian-bagian
Waktu pengiriman: 5-8 hari
Syarat-syarat pembayaran: T/T
Deskripsi Produk
Power input
Rated input voltage (V)

Single-phase 220V (-15%) to 240V (+10%)

Three-phase 220V (-15%) - 240V (+10%)

Three-phase 380V (-15%) - 440V (+10%)

Rated input current (A)

Please refer to "Rated Values of the Product"

Rated frequency (Hz)

50Hz or 60Hz, within the allowable range of 47 to 63Hz

Power output
Rated motor capacity (kW)

Please refer to "Rated Values of the Product"

Rated output (kVA)

Please refer to "Rated Values of the Product"

Rated Current (A)

Please refer to "Rated Values of the Product"

Rated output voltage (V)

Equal to the input voltage, with an error less than 5%

Technical control performance
Control method

Space voltage vector control mode, without PG vector control mode

Motor type

Asynchronous motor

Speed control range

1:100

Speed control accuracy

±0.2% (without PG vector control)

Speed fluctuation

± 0.3% (without PG vector control)

Torque response

(20ms (without PG vector control))

Torque control accuracy

10%

Starting torque

0.5Hz 150% (without PG vector control)

Overload capacity

150% rated current for 1 minute, 180% rated current for 10 seconds, 200% rated current for 1 second

Operating control characteristics
Frequency setting method

Keyboard number setting, analog quantity setting, pulse frequency setting, multi-stage speed running setting, simple PLC setting, PID setting, MODBUS communication setting, etc. Realize the combination of settings and the switching of setting channels.

Carry out the switching of the set combinations and the set channels.

Automatic voltage regulation function

When the grid voltage changes, it can automatically maintain the output voltage constant.

Fault protection function

Provide comprehensive fault protection functions: overcurrent, overvoltage, undervoltage, overheating, phase loss, overload, etc.

Speed tracking restart function

Realize the smooth and impact-free startup of a rotating motor

Simulated input

1st channel (AI2): 0 - 10V / 0 - 20mA, 1st channel (AI3): -10 - 10V

Simulation output

2 channels (AO1, AO2) 0 - 10V / 0 - 20mA

Digital input

4-channel ordinary input, maximum frequency 1kHz

1st speed input, maximum frequency 50kHz

Digital output

Output of terminal Y1 on line 1

Relay output

Two-channel programmable relay outputs

RO1A is normally open, RO1B is normally closed, and RO1C is the common terminal.

RO2A is normally open, RO2B is normally closed, and RO2C is the common terminal.

Contact capacity: 3A/AC250V, 1A/DC30V

Others
DC reactor

Models with a power of 18.5kW and above are equipped with an internal direct reactor as standard.

Installation method

Single-phase 220V/Three-phase 380V 2.2kW (inclusive) and below, Three-phase 220V 0.75kW (inclusive) and below, support both rail-mounted and wall-mounted installation methods.

Three-phase 380V 4kW and above, and three-phase 220V 1.5kW and above support both wall-mounted and flange-mounted installation methods.

Brake unit

For units with power of 37kW or less, the built-in feature is standard. For those with power ranging from 45 to 110kW, the built-in feature is optional.

EMC filter

Three-phase 380V 4kW and above, three-phase 220V 1.5kW and above, with an optional built-in C3 filter; the entire series can be optionally equipped with an external C2 filter.

Optional filters: IEC61800-3 C2, IEC61800-3 C3

Operating environment temperature

-10 to 50 degrees Celsius. For use above 40 degrees Celsius, the performance will be reduced.

Altitude

Below 1000 meters, the usage rate decreases by 1% for every 100 meters increase in altitude. Above 1000 meters, the usage rate decreases by 1% for every 100 meters increase in altitude.

Protection level

IP20

Note: The plastic housing frequency converter should be installed in a metal distribution box that meets IP20 standards, and the top of the box should meet IP3X standards for use.

Safety regulations

Meet the requirements of CE certification

Cooling method

forced air cooling

Rekomendasi Produk
Hubungi kami
Kontak Person : Leon Lee
Tel : +8615389206502
Faks : 86--15389206502
Karakter yang tersisa(20/3000)