| Power Supply | 230 VAC (±10% /-20%), 1-phase / 3-phase compatible Frequency: 45–65 Hz Control Backup: 24 VDC (20–28 VDC) |
| Power and Current | Rated Power: 5.9 kW (6kW 3-phase full power) Single-phase operation: Power reduced to 1/3 Continuous Current: 15 Arms Peak Current: 21 Arms |
| Performance Parameters | PWM Chopper Frequency: 7.5 kHz Output Frequency: 0–500 Hz Analog Command Input: ±10 V differential signal |
| Environmental Conditions | Operating Temperature: 0–50℃ (derating required for 50–60℃) Storage Temperature: -20℃ to 70℃ |
| Weight | Approximately 4 kg |
| Cooling System | Forced air cooling |
| Mounting Options | Standard DIN rail or panel mounting |