Features
Specifications
Operatingtemperature: -10°C To 50°C
Control Type: Closed Loop Vector Control
Feedback Type: Encoder, Resolver, Hall Sensors
Protection Features: Overload, Overvoltage, Overtemperature
Max Frequency: 300HZ
Cooling Method: Fan Cooling
Communicationinterface: EtherCAT/Modbus/RS485
Power Rating: 2000W
Series: D3-S4610
Type: No
Resolution Ratio: NO
Power Range: 0.4-250kw
Model: SSDSC2KG480G801
Output Current: 0-100A
Payment: T/T/Paypal/Western Union/Money Gram
Highlight:

HCS02.1E-W0028-A-03-NNNN

,

Rexroth IndraDrive C 28A

Basic Infomation
Brand Name: Rexroth
Certification: Brand new original
Model Number: HCS02.1E-W0028-A-03-NNNN
Payment & Shipping Terms
Delivery Time: 5-7 days
Payment Terms: T/T
Supply Ability: 10000 USD
Product Description
HCS02.1E-W0028-A-03-NNNN Rexroth Drives
Electrical Parameters
Main Power Supply: Three-phase 200–500 V AC (±10%), 50/60 Hz
Control Power Supply: 24 V DC (±20%)
Switching Frequency: Up to 8 kHz
DC Bus: Supports common DC bus, energy feedback
Brake Chopper: Built-in, supports regenerative braking
Overload Capacity: 2.5 times rated current (short time)
Input Fuse: 20 A
Ideal Connected Load: 4.3 kVA
Model Code Analysis
Code Segment Description
HCS02 IndraDrive C Series (Overseas Version)
1E Hardware Version
W0028 Peak Current 28 A (Continuous 11.3 A)
A Control Unit Type (Basic)
03 Design Version
NNNN No Additional Communication/Security/I/O Expansion (Basic Configuration)
Core Functions and Interfaces
Communication Interface: No built-in fieldbus; requires expansion slots for PROFINET, EtherNet/IP, Modbus TCP, CANopen, Profibus DP
Encoder Interface: Supports Hiperface, EnDat 2.1/2.2, BiSS, SSI, Resolver, TTL
Safety Functions: No built-in safety functions (STO/SS1); requires expansion via safety modules
I/O and Operation: Standard digital I/O and analog interfaces, built-in operation panel (4 keys + digital tube), supports IndraWorks software debugging
Environmental Specifications
Operating Temperature: 0°C – +40°C
Storage Temperature: -25°C – +70°C
Altitude: ≤ 1000 m (higher altitudes require derating)
Installation Spacing: ≥50 mm ventilation space required between drives