Electrical Specifications
Rated input voltage (V)
Three-phase 380V (-20%) to 480V (+10%)
Rated input current (A)
7.4A (Low Overload), 6A (High Overload)
Rated frequency (Hz)
47 to 63Hz
Rated power (kW)
2.2kW (Low Overload), 1.5kW (High Overload)
Rated output (kVA)
3.6kVA
Rated output current (A)
5.6A (Low Overload), 4.1A (High Overload)
Maximum output current (A)
8.2A
Rated output voltage (V)
0 - Input Voltage
Output frequency (Hz)
0~550Hz (V/F control), 0~240Hz (Sensorless Vector Control)
Pulse frequency
4kHz (default), up to 16kHz
Technical Control Performance
Control method
V/F control mode (linear, square, FCC, ECO), without PG sensorless vector control (SLVC) mode
Motor type
Asynchronous motor, permanent magnet synchronous motor, synchronous reluctance motor
Speed control range
1:50 (V/F), 1:100 (SLVC)
Speed control accuracy
±0.5% (without PG vector control)
Overload capacity
150% rated current for 3 seconds, 110% rated current for 57 seconds, 100% rated current for 240 seconds, allowed once every 300 seconds
Operating Control Characteristics
Frequency setting method
Keyboard number setting (optional BOP-2/IOP-2 panel), analog quantity setting, multi-stage speed running setting, simple PLC setting, PID setting, MODBUS RTU/USS communication setting
Safety function
Integrated STO (Safe Torque Off) safety function, SIL2/PL d level
Special functions
PID controller, automatic voltage regulation, speed tracking restart, flying restart, motor parameter auto-tuning, parameter cloning via SD card
Energy saving functions
ECO mode, hibernation mode, real-time energy consumption monitoring
Fault protection function
Overcurrent, overvoltage, undervoltage, overheating, phase loss, overload, ground fault, motor stall, short circuit, etc.
Input/output interfaces
- Digital input: 6-channel opto-isolated general input
- Digital output: 2-channel open collector output
- Analog input: 1 channel, 0(2) to 10V / 0(4) to 20mA
- Analog output: 1 channel, 0 to 10V / 0(4) to 20mA
- Communication: Built-in RS485 interface, supports USS and Modbus RTU protocols (PROFINET/EtherNet/IP optional)
Others
Installation method
Wall-mounted installation, side-by-side installation (no derating)
Brake unit
No built-in brake unit, external optional 6SL3201-0BE14-3AA0
EMC filter
No built-in EMC filter; external C2/C3 filters available as options
Operating environment temperature
-10 to +40 degrees Celsius (derating 1% per degree above 40°C, up to 60°C)
Altitude
Below 1000 meters, no derating required. Above 1000 meters, the rated current decreases by 1% for every 100 meters increase in altitude
Safety regulations
Meet the requirements of CE, UL, cUL, RCM, EAC, RoHS certification
Cooling method
Forced air cooling
Dimensions (H*W*D)
173mm * 73mm * 155mm
Weight
Approximately 1.3kg