| Power input | |
|---|---|
| Rated input voltage (V) | Three-phase 380V (-20%) to 480V (+10%) |
| Rated input current (A) | 1.9A |
| Rated frequency (Hz) | 50Hz or 60Hz, within the allowable range of 47 to 63Hz |
| Power output | |
| Rated motor capacity (kW) | Low overload: 0.55kW High overload: 0.37kW |
| Rated output (kVA) | 0.9kVA |
| Rated Current (A) | 1.9A |
| Rated output voltage (V) | 0 - Input Voltage, with an error less than 5% |
| Output frequency (Hz) | 0~550Hz (V/F control), 0~240Hz (vector control) |
| Technical control performance | |
| Control method | V/F control mode, without PG sensorless vector control (SLVC) mode |
| Motor type | Asynchronous motor, permanent magnet synchronous motor |
| Speed control range | 1:50 (V/F), 1:100 (SLVC) |
| Speed control accuracy | ±0.5% (without PG vector control) |
| Speed fluctuation | ±0.3% (without PG vector control) |
| Torque response | <100ms (without PG vector control) |
| Torque control accuracy | ±15% |
| Starting torque | 1Hz 150% (without PG vector control) |
| Overload capacity | 150% rated current for 3 seconds, 110% rated current for 57 seconds (Low Overload mode) 200% rated current for 3 seconds, 150% rated current for 57 seconds (High Overload mode) |
| Operating control characteristics | |
| Frequency setting method | Keyboard number setting, analog quantity setting, pulse frequency setting, multi-stage speed running setting, simple PLC setting, PID setting, PROFINET/EtherNet/IP communication setting, etc. Realize the combination of settings and the switching of setting channels. |
| Automatic voltage regulation function | When the grid voltage changes, it can automatically maintain the output voltage constant. |
| Fault protection function | Provide comprehensive fault protection functions: overcurrent, overvoltage, undervoltage, overheating, phase loss, overload, ground fault, motor stall, etc. |
| Speed tracking restart function | Realize the smooth and impact-free startup of a rotating motor |
| Simulated input | 1 channel, AI1: 0(2) to 10V / 0(4) to 20mA |
| Simulation output | 1 channel, AO1: 0(4) to 20mA |
| Digital input | 6-channel opto-isolated general input, PNP/NPN selectable, maximum frequency 1kHz |
| Digital output | 2-channel open collector output, maximum frequency 1kHz |
| Relay output | None |
| Others | |
| DC reactor | Not equipped as standard, external optional |
| Installation method | Wall-mounted installation only |
| Brake unit | Built-in brake unit as standard |
| EMC filter | No built-in EMC filter as standard; external C2/C3 filters available as options Optional filters: IEC61800-3 C2, IEC61800-3 C3 |
| Operating environment temperature | -10 to 40 degrees Celsius. For use above 40 degrees Celsius, the performance will be reduced by 1% per degree up to 60°C. |
| Altitude | Below 1000 meters, no derating required. Above 1000 meters, the rated current decreases by 1% for every 100 meters increase in altitude. |
| Protection level | IP20 / UL Open Type |
| Note | The frequency converter should be installed in a metal distribution box that meets IP20 standards, and the top of the box should meet IP3X standards for use. |
| Safety regulations | Meet the requirements of CE, UL, cUL certification, integrated STO (Safe Torque Off) SIL2/PLd |
| Cooling method | Forced air cooling |
| Dimensions (H*W*D) | 173mm * 73mm * 160mm |
| Weight | Approximately 1.3kg |